{"id":295,"date":"2022-11-18T21:34:27","date_gmt":"2022-11-18T21:34:27","guid":{"rendered":"http:\/\/localhost:8888\/surplec2\/?page_id=295"},"modified":"2026-02-16T18:45:59","modified_gmt":"2026-02-16T18:45:59","slug":"cast-resin-transformers","status":"publish","type":"page","link":"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/","title":{"rendered":"TMC Cast Resin Transformers"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Due to the high level of protection against elements related to the encapsulation of coils, TMC transformers can be installed in tight, humid, saline places, as well as in some hostile environments.<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Characteristics:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Self-extinguishing capability<\/li>\n\n\n\n<li>Unlikely moisture penetration<\/li>\n\n\n\n<li>Low risk of environmental hazard<\/li>\n\n\n\n<li>Short-circuit proof<\/li>\n\n\n\n<li>Low maintenance<\/li>\n\n\n\n<li>Suitable for humid, saline, and tropical environments<\/li>\n\n\n\n<li>Easy to repair<\/li>\n\n\n\n<li>Suitable for outdoor installation<\/li>\n\n\n\n<li>Resistance to mechanical shock and vibration<\/li>\n\n\n\n<li>Advantageous dimensions and weight<\/li>\n\n\n\n<li>Transformer cost itself<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Minimal maintenance and quick repair<\/h3>\n\n\n\n<p>The maintenance required is simple and the low voltage &amp; high voltage coils are independent, so they can be replaced quickly and easily. The self-extinguishing characteristics ensure that in the event of internal breakage, the fault is limited and spreading to other phases remains low. Repair costs are greatly reduced.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Very low level of partial discharge<\/h3>\n\n\n\n<p>Given that the level of partial discharge is less than 10 pC, this prevents erosion and breakage of insulation systems of high voltage transformers.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">International accreditations for safety and environment<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ISO 9001:2015 (Quality Assurance)<\/li>\n\n\n\n<li>ISO-14001 (Environmental Management)<\/li>\n\n\n\n<li>OHSAS 18001 (Occupational Health and Safety)<\/li>\n\n\n\n<li>North America: CSA and UL approved<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Low noise emission<\/h3>\n\n\n\n<p>In order to ensure a minimum noise level, special tests are carried out in an anechoic chamber to measure the noise emitted by TMC Cast Resin transformers. A cast transformer has a lower flow rate (dB) than a conventional dry-type transformer.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Power increase potential<\/h3>\n\n\n\n<p>TMC Cast Resin transformers allow for increased power. When your transformer has been installed without a forced cooling system, adding a ventilation system will increase the capacity by approximately 25%<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Due to the high level of protection against elements related to the encapsulation of coils, TMC transformers can be installed in tight, humid, saline places, as well as in some hostile environments. Characteristics: Minimal maintenance and quick repair The maintenance required is simple and the low voltage &amp; high voltage coils are independent, so they [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1385,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-equipment.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-295","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\r\n<title>TMC Cast Resin Transformers - Surplec<\/title>\r\n<meta name=\"description\" content=\"The maintenance required for TMC encapsulated transformers is simple, and the low-voltage and high-voltage coils are independent.\" \/>\r\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\r\n<link rel=\"canonical\" href=\"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/\" \/>\r\n<meta property=\"og:locale\" content=\"en_US\" \/>\r\n<meta property=\"og:type\" content=\"article\" \/>\r\n<meta property=\"og:title\" content=\"TMC Cast Resin Transformers - Surplec\" \/>\r\n<meta property=\"og:description\" content=\"The maintenance required for TMC encapsulated transformers is simple, and the low-voltage and high-voltage coils are independent.\" \/>\r\n<meta property=\"og:url\" content=\"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/\" \/>\r\n<meta property=\"og:site_name\" content=\"Surplec\" \/>\r\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/surplecinc\/\" \/>\r\n<meta property=\"article:modified_time\" content=\"2026-02-16T18:45:59+00:00\" \/>\r\n<meta property=\"og:image\" content=\"https:\/\/www.surplec.com\/wp-content\/uploads\/2023\/04\/surplec-cast-resin.jpg\" \/>\r\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\r\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\r\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\r\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\r\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\r\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/\",\"url\":\"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/\",\"name\":\"TMC Cast Resin Transformers - Surplec\",\"isPartOf\":{\"@id\":\"https:\/\/www.surplec.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.surplec.com\/wp-content\/uploads\/2023\/04\/surplec-cast-resin.jpg\",\"datePublished\":\"2022-11-18T21:34:27+00:00\",\"dateModified\":\"2026-02-16T18:45:59+00:00\",\"description\":\"The maintenance required for TMC encapsulated transformers is simple, and the low-voltage and high-voltage coils are independent.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/#breadcrumb\"},\"inLanguage\":\"en-CA\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-CA\",\"@id\":\"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/#primaryimage\",\"url\":\"https:\/\/www.surplec.com\/wp-content\/uploads\/2023\/04\/surplec-cast-resin.jpg\",\"contentUrl\":\"https:\/\/www.surplec.com\/wp-content\/uploads\/2023\/04\/surplec-cast-resin.jpg\",\"width\":1080,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.surplec.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"TMC Cast Resin Transformers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.surplec.com\/en\/#website\",\"url\":\"https:\/\/www.surplec.com\/en\/\",\"name\":\"Surplec\",\"description\":\"Un site utilisant WordPress\",\"publisher\":{\"@id\":\"https:\/\/www.surplec.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.surplec.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-CA\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.surplec.com\/en\/#organization\",\"name\":\"Surplec\",\"url\":\"https:\/\/www.surplec.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-CA\",\"@id\":\"https:\/\/www.surplec.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.surplec.com\/wp-content\/uploads\/2024\/09\/logo-surplec-rev-en.jpg\",\"contentUrl\":\"https:\/\/www.surplec.com\/wp-content\/uploads\/2024\/09\/logo-surplec-rev-en.jpg\",\"width\":400,\"height\":400,\"caption\":\"Surplec\"},\"image\":{\"@id\":\"https:\/\/www.surplec.com\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/surplecinc\/\"]}]}<\/script>\r\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TMC Cast Resin Transformers - Surplec","description":"The maintenance required for TMC encapsulated transformers is simple, and the low-voltage and high-voltage coils are independent.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/","og_locale":"en_US","og_type":"article","og_title":"TMC Cast Resin Transformers - Surplec","og_description":"The maintenance required for TMC encapsulated transformers is simple, and the low-voltage and high-voltage coils are independent.","og_url":"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/","og_site_name":"Surplec","article_publisher":"https:\/\/www.facebook.com\/surplecinc\/","article_modified_time":"2026-02-16T18:45:59+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/www.surplec.com\/wp-content\/uploads\/2023\/04\/surplec-cast-resin.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/","url":"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/","name":"TMC Cast Resin Transformers - Surplec","isPartOf":{"@id":"https:\/\/www.surplec.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/#primaryimage"},"image":{"@id":"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/#primaryimage"},"thumbnailUrl":"https:\/\/www.surplec.com\/wp-content\/uploads\/2023\/04\/surplec-cast-resin.jpg","datePublished":"2022-11-18T21:34:27+00:00","dateModified":"2026-02-16T18:45:59+00:00","description":"The maintenance required for TMC encapsulated transformers is simple, and the low-voltage and high-voltage coils are independent.","breadcrumb":{"@id":"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/#breadcrumb"},"inLanguage":"en-CA","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.surplec.com\/en\/cast-resin-transformers\/"]}]},{"@type":"ImageObject","inLanguage":"en-CA","@id":"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/#primaryimage","url":"https:\/\/www.surplec.com\/wp-content\/uploads\/2023\/04\/surplec-cast-resin.jpg","contentUrl":"https:\/\/www.surplec.com\/wp-content\/uploads\/2023\/04\/surplec-cast-resin.jpg","width":1080,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/www.surplec.com\/en\/cast-resin-transformers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.surplec.com\/en\/"},{"@type":"ListItem","position":2,"name":"TMC Cast Resin Transformers"}]},{"@type":"WebSite","@id":"https:\/\/www.surplec.com\/en\/#website","url":"https:\/\/www.surplec.com\/en\/","name":"Surplec","description":"Un site utilisant WordPress","publisher":{"@id":"https:\/\/www.surplec.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.surplec.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-CA"},{"@type":"Organization","@id":"https:\/\/www.surplec.com\/en\/#organization","name":"Surplec","url":"https:\/\/www.surplec.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-CA","@id":"https:\/\/www.surplec.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.surplec.com\/wp-content\/uploads\/2024\/09\/logo-surplec-rev-en.jpg","contentUrl":"https:\/\/www.surplec.com\/wp-content\/uploads\/2024\/09\/logo-surplec-rev-en.jpg","width":400,"height":400,"caption":"Surplec"},"image":{"@id":"https:\/\/www.surplec.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/surplecinc\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.surplec.com\/en\/wp-json\/wp\/v2\/pages\/295","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.surplec.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.surplec.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.surplec.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.surplec.com\/en\/wp-json\/wp\/v2\/comments?post=295"}],"version-history":[{"count":16,"href":"https:\/\/www.surplec.com\/en\/wp-json\/wp\/v2\/pages\/295\/revisions"}],"predecessor-version":[{"id":12607,"href":"https:\/\/www.surplec.com\/en\/wp-json\/wp\/v2\/pages\/295\/revisions\/12607"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.surplec.com\/en\/wp-json\/wp\/v2\/media\/1385"}],"wp:attachment":[{"href":"https:\/\/www.surplec.com\/en\/wp-json\/wp\/v2\/media?parent=295"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}